xCELLigence RTCA MP - Multiple plates
Obtain continuous cell assay data points using label-free methods, in a 6 x 96-well format
Run up to six 96-well plates simultaneously or independently
Easy workflow
Intuitive RTCA Software Pro

Information

The Agilent xCELLigence Real-Time Cell Analysis (RTCA) MP instrument uses label-free cellular impedance to continuously monitor cell health, behavior, and function with high accuracy, sensitivity, and reproducibility.

The MP model can host up to six 96-well electronic microplates (E-Plate 96), which can be run in parallel or independently of one another. This multiple plate format is ideal for cell health characterization, immune cell-mediated killing, viral cytopathic effects, cytotoxicity, cell adhesion, cell barrier function (TEER), cell signaling (e.g., GPCR) and other related applications.

The instrument operates in a standard CO2 cell culture incubator and the control unit is housed outside the incubator. Simply plate cells and begin monitoring cell behavior to obtain real-time kinetic data for assay windows that stretch from seconds to days. Online data acquisition and offline data analysis are easy to perform using RTCA Software Pro, which also supports FDA 21 CFR Part 11.

 

Key features:

  • xCELLigence RTCA MP model can run up to six 96-well plates simultaneously or independently, with flexible plate batch processing to maximize productivity for multiple users
  • MP system measures cell health, viability, or response to treatments with high sensitivity, accuracy, and reproducibility
  • RTCA MP analyzer obtains continuous data at high temporal resolution (from seconds to days), with non-invasive and label-free real-time impedance technology
  • Easy workflow allows users to simply add cells to E-plates and begin kinetic measurements at physiological conditions, with minimal hands-on time
  • Intuitive RTCA Software Pro allows for analysis of real-time data to generate diverse plot types and automatically calculate parameters such as % of cytolysis, IC50 or KT50
  • RTCA Software Pro supports FDA 21 CFR Part 11 compliance to ensure electronic data integrity
Analyzer Application Adhesion Apoptosis Cell Characterization
Cytotoxity Immune Cell Killing Proliferation
Receptor Signaling Stem Cells Virus Cytopathic Effects
Wound Healing
Depth 18 cm
Height 18 cm
Operating Environment Relative Humidity 5-98 %
Operating Environment Temperature 20-40 °C
Sampling Format 6 x 96 wells plates
Width 44 cm

Immune Cell Killing Assays

Typical immune cell killing assays are labor-intensive and require users to collect multiple timepoints using a combination of techniques. In contrast, the label-free xCELLigence RTCA instruments provide a complete view of immune cell killing and closely mimics activity in vivo. Obtain highly sensitive, reproducible, and direct measurements of immune cell killing potency in real time. This simple and high throughput workflow also provides greater insight into cellular mechanism of action, serial killing, and exhaustion.  

Viral Cytopathic Effect Assays

Advance your anti-viral therapy or vaccine development by accurately measuring viral cytopathic effects (CPE) in real time with Agilent xCELLigence RTCA instruments, without the use of labor-intensive plaque assays. Monitor viral CPE automatically, from minutes to days, and greatly reduce workload and manual handling of samples. Measure cell proliferation kinetics, identify the optimal time point for viral infection with different cell seeding densities, and assess virus-mediated cytopathogenicity in one workflow.  

Cytotoxicity Assays

Determine cytotoxic effects of drugs or compounds by monitoring cell proliferation, cell size or morphology, and cell-substrate attachment quality in real time. Monitor the kinetics of long-term cellular responses with this simple and high-throughput cytotoxicity assay. Make informed decisions about the timing of cell treatments and easily generate dose-response curves at multiple time points, without increasing the workload.  

Cell Adhesion Assays

During tumor formation, primary cancers shed millions of cells into circulation, which are known as circulating tumor cells (CTCs). CTCs can re-attach, extravasate, and metastasize in distant organs.  With xCELLigence RTCA, continuously monitor cell adhesion kinetics of different cell types to gain deeper insight into the intricacy of metastasis. Quantitatively assess cell attachment and spreading in real time, without the use of fluorescent reagents or dyes.  

Cell Signaling Assays

G protein-coupled receptor (GPCR), receptor tyrosine kinase (RTK), or nuclear hormone-mediated signaling often results in biochemical changes that affect the number of cells present, the size/morphology of the cells, and how tightly the cells are interacting with the plate surface. With xCELLigence RTCA, you can sensitively capture changes in cell size, shape, and proliferation rate in response to cell signaling events. This label-free and continuous monitoring provides quantitative assessment of cell response in the initial minutes of exposure and their response over days.  

Stem Cell Assays

Stem cell research provides mechanistic insights into disease, aids regenerative medicine development, and offers an alternative approach to test the liability and effectiveness of new drugs. Overcome cell therapy manufacturing challenges by predicting functional capacity and assessing variability of mesenchymal stem cells (MSCs) with xCELLigence RTCA. Maximize production yields using fewer cells and continuously measure integrated changes in cell number, attachment, and morphology to ensure consistency between passages.  

Cell Barrier Function Assays

Cell barrier function, provided by endothelial and epithelial cells, can become compromised in many disease states. Endothelial cells line the interior surface of blood vessels and lymphatic vessels. Epithelial cells form the surfaces of the body that serve as a barrier to protect from foreign molecules. The impedance-based xCELLigence RTCA assay is a sensitive and quantitative alternative to the traditional methods to measure barrier disruption, including the solute permeability assay and transendothelial electrical resistance (TEER) assay.
How is xCELLigence RTCA used for killing assays? The xCELLigence Real-Time Cell Analysis (RTCA) instrument monitors cell killing in real time. Simply add target and immune effector cells to the patented microtiter plates (E-Plates), load the instrument, and start reading. The biosensors embedded in the bottom of each well allow for the automated kinetic measurement of changes in cell number, size, and substrate attachment quality. Target cell death can be measured continuously and automatically from hours to days without the use of labels.
 
Simple and high throughput workflow The xCELLigence Real-Time Cell Analysis (RTCA) instruments utilize patented microplates (E-Plates) containing gold biosensors embedded in the bottom of each well. These biosensors continuously and noninvasively monitor changes in cell number, cell size, and cell-substrate attachment quality.
 
Accurate and reproducible cytolytic data with xCELLigence RTCA Software Pro xCELLigence RTCA Software Pro is an integrated software package that includes a powerful immunotherapy module for running and analyzing real time cell analysis data.Real time effector cytolysis can be consistently calculated at low and physiologically relevant, effector to target ratios.

Related instruments

xCELLigence_eSight_web
xCELLigence RTCA eSight
Combining label-free impedance technology with brightfield imaging
Whole well imaging expansion
3 fluorescent channels spanning
Single setup for dual measurements
xcelligence-dp
xCELLigence RTCA DP
Make continuous measurements of cell invasion and migration (CIM) using an electronically integrated Boyden chamber
Monitoring of cell invasion and migration in real-time
Non-invasive and label-free real-time impedance assay
FDA 21 CFR Part 11 compliance
xcelligence-rtca-s16
xCELLigence RTCA S16 - Pilot scale
Continously monitor live cell proliferation, morphology change, and attachment quality in a label-free and real-time manner
Continously monitoring of live cell proliferation, morphology change, and attachment quality
Non-invasive and label-free real-time analysis

Recently viewed instruments

No links are found